The Asset Track Pro Smart Ultrasonic Water Meter uses advanced ultrasonic transit-time technology for highly accurate flow measurement, capable of detecting flow as low as 0.01 m³/h, compliant with OIML R49/MID standards. It features micro-power technology with an 8+ year battery life (ER26500, customizable to ER34615), compact size, strong anti-interference, and stable performance. It supports multi-angle installation without affecting accuracy or causing pressure loss. Ideal for residential use, it includes LoRa connectivity and can integrate with a wireless monitoring system via GSM or Ethernet for real-time data and abnormality alerts.

 

Technical Specifications:

DN15 DN20 DN25 DN32 DN40
Range & Capacity- R250
Q3 (Qmax/permanent) 2.500m3/h 4.000m3/h 6.300m3/h 10.00m3/h 16.00m3/h
Q4 (Qoverload) 3.125m3/h 5.000m3/h 7.875m3/h 12.50m3/h 20.00m3/h
Q2 (Qtransitional) 0.016m3/h 0.025m3/h 0.040m3/h 0.064m3/h 0.102m3/h
Q1 (Qmin) 0.010m3/h 0.016m3/h 0.025m3/h 0.040m3/h 0.064m3/h
Start Flow rate 0.002m3/h 0.002m3/h 0.003m3/h 0.005m3/h 0.005m3/h
Dynamic Range R250
Range & Capacity- R400
Q3 (Qmax/permanent) 2.500m3/h 4.000m3/h 6.300m3/h 10.00m3/h 16.00m3/h
Q4 (Qoverload) 3.125m3/h 5.000m3/h 7.875m3/h 12.50m3/h 20.00m3/h
Q2 (Qtransitional) 0.010m3/h 0.016m3/h 0.025m3/h 0.040m3/h 0.064m3/h
Q1 (Qmin) 0.006m3/h 0.010m3/h 0.016m3/h 0.025m3/h 0.040m3/h
Start Flow rate 0.002m3/h 0.002m3/h 0.003m3/h 0.005m3/h 0.005m3/h
Dynamic Range R400
Standard ISO4064: 2014 / OIML: R49-2013
Measured medium Water, homogeneous liquid, and filled with measured pipes.
Battery 3.6V, Li-battery    /ER34615
Battery Life ≥8 Years
Consumption <0.2mW
Pressure loss DN15-DN20: Δp40             DN25-DN40:   Δp63
EMC E1
Environmental Classification Class B
Protection Class IP68
Medium Temperature T30(
Storage Temperature -25℃ to 55℃
MAP PN16
Accuracy ±5% in range Q1≤Q<Q2
±2% in range Q2≤Q≤Q4
Head Loss 0.4bar@Q3
Sensitivity of upstream flow field U10
Sensitivity of downstream flow

field

D5

 

Description

Overview:

The Asset Track Pro Smart Ultrasonic Water Meter uses advanced ultrasonic transit-time technology for highly accurate flow measurement, capable of detecting flow as low as 0.01 m³/h, compliant with OIML R49/MID standards. It features micro-power technology with an 8+ year battery life (ER26500, customizable to ER34615), compact size, strong anti-interference, and stable performance. It supports multi-angle installation without affecting accuracy or causing pressure loss. Ideal for residential use, it includes LoRa connectivity and can integrate with a wireless monitoring system via GSM or Ethernet for real-time data and abnormality alerts.

 

Technical Specifications:

DN15 DN20 DN25 DN32 DN40
Range & Capacity- R250
Q3 (Qmax/permanent) 2.500m3/h 4.000m3/h 6.300m3/h 10.00m3/h 16.00m3/h
Q4 (Qoverload) 3.125m3/h 5.000m3/h 7.875m3/h 12.50m3/h 20.00m3/h
Q2 (Qtransitional) 0.016m3/h 0.025m3/h 0.040m3/h 0.064m3/h 0.102m3/h
Q1 (Qmin) 0.010m3/h 0.016m3/h 0.025m3/h 0.040m3/h 0.064m3/h
Start Flow rate 0.002m3/h 0.002m3/h 0.003m3/h 0.005m3/h 0.005m3/h
Dynamic Range R250
Range & Capacity- R400
Q3 (Qmax/permanent) 2.500m3/h 4.000m3/h 6.300m3/h 10.00m3/h 16.00m3/h
Q4 (Qoverload) 3.125m3/h 5.000m3/h 7.875m3/h 12.50m3/h 20.00m3/h
Q2 (Qtransitional) 0.010m3/h 0.016m3/h 0.025m3/h 0.040m3/h 0.064m3/h
Q1 (Qmin) 0.006m3/h 0.010m3/h 0.016m3/h 0.025m3/h 0.040m3/h
Start Flow rate 0.002m3/h 0.002m3/h 0.003m3/h 0.005m3/h 0.005m3/h
Dynamic Range R400
Standard ISO4064: 2014 / OIML: R49-2013
Measured medium Water, homogeneous liquid, and filled with measured pipes.
Battery 3.6V, Li-battery    /ER34615
Battery Life ≥8 Years
Consumption <0.2mW
Pressure loss DN15-DN20: Δp40             DN25-DN40:   Δp63
EMC E1
Environmental Classification Class B
Protection Class IP68
Medium Temperature T30(
Storage Temperature -25℃ to 55℃
MAP PN16
Accuracy ±5% in range Q1≤Q<Q2
±2% in range Q2≤Q≤Q4
Head Loss 0.4bar@Q3
Sensitivity of upstream flow field U10
Sensitivity of downstream flow

field

D5