| Display |
4.3-inch capacitive touchscreen, 800×480 resolution |
| Integrated Functions |
OTDR, Event Map, OPM, LS, VFL, RJ45 Testing, Microscope, Flashlight, Insertion Loss Test |
| Memory |
8 GB, stores over 200,000 curves |
| Connectors |
FC/UPC (interchangeable with SC, ST) |
| Dynamic Range |
24 dB to 30 dB, depending on the model |
| Wavelength |
1310 nm, 1550 nm, 1625 nm, 1650 nm, based on model |
| Event Dead Zone |
≤ 4.92 ft (1.5 m) |
| Attenuation Dead Zone |
26.25 ft (8 m) |
| Test Range |
328 ft to 161 mi (0.1 km to 260 km) |
| Pulse Width |
3 ns to 20 µs |
| Distance Measurement Accuracy |
±(3.28 ft + sampling interval + 0.005% × test distance) |
| Linearity |
≤ 0.05 dB/dB |
| Maximum Sampling Points |
≥ 160,000 |
| Distance Resolution |
0.0033 ft (0.001 m) |
| RJ45 Cable Test |
Cable tracking and sequencing, test length ≤ 984.25 ft (300 m) |
| Operating Temperature |
14°F to 122°F (-10°C to +50°C) |
| Dimensions |
7.44 in x 4.53 in x 1.69 in (18.9 cm x 11.5 cm x 4.3 cm) |
| Weight |
≤ 1.32 lb. (0.6 kg) |