| Electrical |
| Regulatory Compliance |
RoHS, CE 0682 |
| Frequency Range |
902 – 928 MHz |
| Gain |
6.5 dBic (min) 7.5 dBic (max) |
| 0VSWR |
1.3 :1 (typical) , 1.5 : 1 (max) |
| Polarization |
LHCP |
| 3DB Elevation Beamwidth |
75° (typical) |
| 3DB Azimuth Beamwidth |
75° (typical) |
| F/B Ratio |
-15 dB (typical) |
| Power |
6 W (max) |
| Input Impedance |
50 Ω |
| Axial Ratio at Boresight |
3.5 dB (max) |
| Lightning Protection |
DC Grounded |
| Mechanical |
| Dimensions (L × W × D) |
190 × 190 × 30 mm |
| Connector |
Right angle N-Type female |
| Weight |
2 kg (max) |
| Structure |
Flat antenna housed in Aluminum with chemical conversion coating enclosure |
| Outline Drawing |
RD42815500C |
| Environmental |
| Test |
Standard |
Duration |
Temperature |
Notes |
| Low Temperature |
IEC 68-2-1 |
72 h |
-55 °C |
|
| High Temperature |
IEC 68-2-2 |
72 h |
+71 °C |
|
| Temp. Cycling |
IEC 68-2-14 |
1 h |
-45 °C to +70 °C |
3 Cycles |
| Thermal Shock NONO-Operating |
|
|
-30°C to+70°C |
Ramp 30 °C/min |
| Humidity |
ETSI EN300-2-4 T4.1E |
144 h |
|
95 % |
| Water Tightness |
IEC 529 |
|
|
IP66 |
| Dust Resistance |
|
|
|
IP66 |
| Solar Radiation |
ASTM G53 |
1000h |
|
|
| Ozone Resistance |
ETSI 300 |
|
|
|
| Flammability |
UL 94 |
|
|
Class HB |
| Quasi Random Vibration |
|
|
|
20 g rms for 4 hours |
| Vehicle Vibration Operating |
1 grms, 10-500 Hz, in 3 axis |
|
|
6 hours total, 2 hr in each axis. Accelerated wear-an additional 50hrs in worst case axis. |
| Mechanical Shock Operating |
10 g, 11 msec, half sine pulse |
|
|
|