| Pulse Reflection Test Maximum Range |
4.97 miles / 9.94 miles / 19.88 miles (8 km / 16 km / 32 km optional) |
| Test Blind Zone |
0 ft |
| Test Accuracy |
Up to 3.28 ft (1 m) |
| Pulse Width |
40ns to 10μs automatic adjustment |
| Automatic Impedance Balance Adjustment |
Yes |
| Gain Adjustment |
Automatic and manual combination |
| Testable DC Voltage |
-400 V to 400 V |
| Testable AC Voltage |
0 V to 290 V |
| Testable Circuit Capacitance |
0 nF to 1000 nF |
| Accuracy (Capacitance) |
0 nF to 10 nF: ± 2 nF, 10 nF to 1000 nF: ±2% ±2 nF |
| Measure Ring Resistance |
0 Ω to 20 kΩ |
| Accuracy (Resistance) |
0 Ω to 100 Ω: ±3% ±4Ω, 100 Ω to 500 Ω: ±3%, 500 KΩ to 20 KΩ: ±2% |
| Insulation Resistance |
0 MΩ to 30 MΩ |
| Accuracy (Insulation Resistance) |
0 MΩ to 1.0 MΩ: ±0.1 MΩ, 1.0 MΩ to 30 MΩ: ±10% ±0.5 MΩ |
| Charging Time |
About 3.5 hours |
| Continuous Working Time |
8 hours after full charge |
| Volume |
8.27 in x 6.53 in x 3.54 in (21 cm x 16.6 cm x 9 cm) |
| Weight |
2.2 lbs (1 kg) |