| Processor |
Up to Four 4th Generation Intel Xeon Scalable Processors with Up to 60 Cores per Processor and with Optional Intel® QuickAssist Technology |
| Memory |
64 DDR5 DIMM Slots, Supports RDIMM 16TB Max, Speeds Up to 4800MT/s, Supports Registered ECC DDR5 DIMMs Only |
| Storage Controllers |
Internal Controllers: PERC H965i, PERC H755, PERC H355, HBA355i, External Controller: PERC H965e, Internal Boot: Boot Optimized Storage Subsystem (BOSS-N1): HWRAID 2 x M.2 NVMe SSDs or USB, External HBA (Non-RAID): HBA355e, Software RAID: S160 |
| Drive Bays |
Front Bays: Up to 8 x 2.5-Inch SAS or SATA (HDD or SSD) Max 122.88TB, Up to 16 x 2.5-Inch SAS or SATA (HDD or SSD) Max 245.76TB, Up to 24 x 2.5-Inch NVMe (SSD) Max 368.64TB, Up to 16 x 2.5-Inch SAS or SATA (HDD or SSD) + 8 x 2.5-Inch NVMe (SSD) Max 368.64TB, Up to 32 x 2.5-Inch SAS or SATA (HDD or SSD) Max 491.52TB, Up to 16 x EDSFF E3.S Gen5 NVMe (SSD) Max 122.88TB, Up to 16 x EDSFF E3.S Gen5 NVMe (SSD) + 8 x 2.5-Inch SAS or SATA (HDD or SSD) Max 245.76TB |
| Power Supplies |
1100W Titanium 100 to 240VAC or 240HVDC Hot-Swap Redundant, 1400W Platinum 100 to 240VAC or 240HVDC Hot-Swap Redundant, 1800W Titanium 200 to 240VAC or 240HVDC Hot-Swap Redundant, 2400W Platinum 100 to 240VAC or 240HVDC Hot-Swap Redundant, 2800W Titanium 200 to 240VAC or 240HVDC Hot-Swap Redundant |
| Cooling Options |
Air Cooling, Optional Direct Liquid Cooling (DLC) |
| Fans |
Standard (STD) Fans, Up to 6 Sets (Dual Fan Module) Hot-Plug Fans |
| Dimensions |
6.86 in x 18.97 in x 34.77 in (174.3 mm x 482 mm x 883.195 mm) |
| Form Factor |
4U Rack Server |
| Embedded Management |
iDRAC9, iDRAC Direct, iDRAC RESTful API with Redfish, iDRAC Service Module, Quick Sync 2 Wireless Module |
| Bezel |
Optional LCD Bezel or Security Bezel |
| OpenManage Software |
CloudIQ for PowerEdge Plug-In, OpenManage Enterprise, OpenManage Enterprise Integration for VMware vCenter, OpenManage Integration for Microsoft System Centre, OpenManage Integration with Windows Admin Centre, OpenManage Power Manager Plug-In, OpenManage Service Plug-In, OpenManage Update Manager Plug-In |
| Mobility |
OpenManage Mobile |
| Open Manage Integrations |
BMC TrueSight, Microsoft System Centre, OpenManage Integration with ServiceNow, Red Hat Ansible Modules, Terraform Providers, VMware vCenter and vRealize Operations Manager |
| Security |
Cryptographically Signed Firmware, Data at Rest Encryption (SEDs with Local or External Key Management), Secure Boot, Secure Erase, Secured Component Verification (Hardware Integrity Check), Silicon Root of Trust, System Lockdown (Requires iDRAC9 Enterprise or Datacentre), TPM 2.0 FIPS, CC-TCG Certified, TPM 2.0 China NationZ |
| Embedded NIC |
2 x 1 GbE LOM Card (Optional) |
| Network Options |
1 x OCP Card 3.0 (Optional), Note: The System Allows Either LOM Card or an OCP Card or Both to Be Installed in the System |