Micro Module Dimensions Single Channel (with aisle containment) L x 2,200 mm x 2,300 mm / L x 2,200 mm x 2,400 mm / L x 2,400 mm x 2,300 mm / L x 2,400 mm x 2,400 mm / Customized
Micro Module Dimensions Double Channel (with aisle containment) L x 3,200 mm x 2,300 mm / L x 3,200 mm x 2,400 mm / L x 3,600 mm x 2,300 mm / L x 3,600 mm x 2,400 mm / Customized
Micro Module Cabinets Per Module Single channel ≤ 24 cabinets; Dual channel ≤ 48 cabinets
Micro Module Power Supply 208V/380V/400V/415V DC/AC, 50 Hz/60 Hz, 3 Ph + N + PE
Micro Module Max IT Load Per Module 125 kW (with integrated UPS) / 145 kW (with integrated PDC) / 235 kW (with precision PDC)
Micro Module Cable Routing Routed in/out through the top of cabinets
Micro Module Installation Installing on raised floor
Cabinet Dimensions (H x W x D) 2,000 mm x 600/800 mm x 1,200 mm / 2,000 mm x 600/800 mm x 1,100 mm / 2,200 mm x 600/800 mm x 1,200 mm
Space Available 42U/47U
Protection Level IP20
Air Conditioner Installation In-Row or vertical direction of one end
Refrigeration Direct expansion air cooling, chilled water, and cooling water system
In-Row Air Conditioner Cooling capacity: Optional
Dimensions (H x W x D) 2,000 mm x 300 mm x D / 2,000 mm x 600 mm x D
Power Supply 208V/380V~415V AC, 50 Hz/60 Hz, 3 Ph + N + PE
Refrigerant R410A / R407C
Integrated UPS
Input Voltage
208V/380V/400V/415V AC, 50 Hz/60 Hz, 3 Ph + N + PE
Input 250A/400A MCCB
Input Power Factor Full load > 0.99, Half load > 0.98
Output Power Factor 1
Rated Capacity 25 kVA~125 kVA
Output IT: 40A/1P x 24 x 2; A/C: 40A or 63A/3P x 8; Lighting: 10A/1P x 3
Efficiency ≥ 96%
Integrated Power Distribution Cabinet (UPS outside)
Input Voltage
380V/400V/415V AC, 50Hz/60Hz, 3 Ph + N + PE
Input IT: 160A/250A MCCB; A/C: 160/250A MCCB
Rated Input Current IT: 160A/250A, A/C: 160A/250A
Output IT: 32A/1P x 2 per cabinet; A/C: 40A or 63A/3P per; Lighting: 10A/1P
Precision Power Distribution Cabinet (UPS outside)
Input Voltage
208V/380V/400V/415V AC, 50 Hz/60 Hz, 3 Ph + N + PE
Input 160A/250A/400A MCCB
Output 32A/1P, maximum 144 routes
Smart Bus Bar (UPS outside) Input Voltage 208V/380V/400V/415V AC, 50 Hz/60 Hz, 3 Ph + N + PE
Input 160A/250A MCCB
Output 32A/1P

Description

Technical Specifications

Micro Module Dimensions Single Channel (with aisle containment) L x 2,200 mm x 2,300 mm / L x 2,200 mm x 2,400 mm / L x 2,400 mm x 2,300 mm / L x 2,400 mm x 2,400 mm / Customized
Micro Module Dimensions Double Channel (with aisle containment) L x 3,200 mm x 2,300 mm / L x 3,200 mm x 2,400 mm / L x 3,600 mm x 2,300 mm / L x 3,600 mm x 2,400 mm / Customized
Micro Module Cabinets Per Module Single channel ≤ 24 cabinets; Dual channel ≤ 48 cabinets
Micro Module Power Supply 208V/380V/400V/415V DC/AC, 50 Hz/60 Hz, 3 Ph + N + PE
Micro Module Max IT Load Per Module 125 kW (with integrated UPS) / 145 kW (with integrated PDC) / 235 kW (with precision PDC)
Micro Module Cable Routing Routed in/out through the top of cabinets
Micro Module Installation Installing on raised floor
Cabinet Dimensions (H x W x D) 2,000 mm x 600/800 mm x 1,200 mm / 2,000 mm x 600/800 mm x 1,100 mm / 2,200 mm x 600/800 mm x 1,200 mm
Space Available 42U/47U
Protection Level IP20
Air Conditioner Installation In-Row or vertical direction of one end
Refrigeration Direct expansion air cooling, chilled water, and cooling water system
In-Row Air Conditioner Cooling capacity: Optional
Dimensions (H x W x D) 2,000 mm x 300 mm x D / 2,000 mm x 600 mm x D
Power Supply 208V/380V~415V AC, 50 Hz/60 Hz, 3 Ph + N + PE
Refrigerant R410A / R407C
Integrated UPS
Input Voltage
208V/380V/400V/415V AC, 50 Hz/60 Hz, 3 Ph + N + PE
Input 250A/400A MCCB
Input Power Factor Full load > 0.99, Half load > 0.98
Output Power Factor 1
Rated Capacity 25 kVA~125 kVA
Output IT: 40A/1P x 24 x 2; A/C: 40A or 63A/3P x 8; Lighting: 10A/1P x 3
Efficiency ≥ 96%
Integrated Power Distribution Cabinet (UPS outside)
Input Voltage
380V/400V/415V AC, 50Hz/60Hz, 3 Ph + N + PE
Input IT: 160A/250A MCCB; A/C: 160/250A MCCB
Rated Input Current IT: 160A/250A, A/C: 160A/250A
Output IT: 32A/1P x 2 per cabinet; A/C: 40A or 63A/3P per; Lighting: 10A/1P
Precision Power Distribution Cabinet (UPS outside)
Input Voltage
208V/380V/400V/415V AC, 50 Hz/60 Hz, 3 Ph + N + PE
Input 160A/250A/400A MCCB
Output 32A/1P, maximum 144 routes
Smart Bus Bar (UPS outside) Input Voltage 208V/380V/400V/415V AC, 50 Hz/60 Hz, 3 Ph + N + PE
Input 160A/250A MCCB
Output 32A/1P